搜索结果: 1-15 共查到“化学 sensor”相关记录17条 . 查询时间(0.078 秒)
Nile Blue-hexacyanoferrate carbon paste modified electrode as an amperometric sensor for determination of hydrazine
Modified electrode carbon paste electrode hexacyanoferrate
2010/12/29
The main problem associated with metal hexacyanoferrates (MHCFs) is their instability at high pH values. We synthesized a new Prussian Blue analogue, Nile-Blue hexacyanoferrate (NBHCF), that remains s...
Nile Blue-hexacyanoferrate carbon paste modified electrode as an amperometric sensor for determination of hydrazine
Modified electrode carbon paste electrode hexacyanoferrate amperometric determination of hydrazine Nile-Blue hexacyanoferrate
2010/12/20
The main problem associated with metal hexacyanoferrates (MHCFs) is their instability at high pH values. We synthesized a new Prussian Blue analogue, Nile-Blue hexacyanoferrate (NBHCF), that remains s...
Sensor Properties and Surface Characterization of Silver-deposited SPR Optical Fibers
Sensor Properties and Surface Characterization of Silver-deposited SPR Optical Fibers
2010/9/17
The response curves and sensor properties of silver-deposited optical fibers with Ag film thicknesses of 20.0 − 80.0 nm based on surface plasmon resonance (SPR) were investigated. The response o...
A Reflectance Flow-through Thionine Sol-gel Sensor for the Determination of Se(IV)
Reflectance Flow-through Thionine Sol-gel Sensor Determination of Se
2010/9/13
In this work, a reversible sensor to assess the total Se(IV) content in samples is described. Pre-activated glass slides were spin-coated with 100 μL of a 20-h aged sol-gel mixture of 1 mL of tetrame...
A Highly Selective Fluorescent Sensor for Cu2+ Based on a Covalently Immobilized Naphthalimide Derivative
Fluorescent Sensor Cu2+ Naphthalimide Derivative
2010/9/20
In this paper, we describe the fabrication and analytical characteristics of fluorescence-based copper ion-sensing glass slides. To construct the sensor, a naphthalimide derivative N-allyl-4-(bis(pyr...
Fabrication of an Implantable Fine Needle-Type Glucose Sensor Using γ -Polyglutamic Acid
Implantable Fine Needle-Type Glucose Sensor γ -Polyglutamic Acid
2010/9/20
Implantable fine needle-type glucose sensors with an outer diameter of less that 0.2 mm were fabricated using a low-cost and non-animal origin polyamide, γ-polyglutamic acid (PGA) as a glucose oxidas...
A Flow-through Electrochemiluminescence Sensor for Salt Stress on Rice Plants
A Flow-through Electrochemiluminescence Sensor Salt Stress Rice Plants
2010/9/19
Cultivation of rice plants (Koshihikari, IR4595 and IR28) in 250 mmol/L NaCl over 16 days provided interesting profiles of responses on a flow-through electrochemiluminescence (ECL) system with tris(2...
Electrochemical Gene Sensor Arrays Prepared Using Non-contact Nanoliter Array Spotting of Gene Probes
Electrochemical Gene Sensor Arrays Non-contact Nanoliter Array Spotting Gene Probes
2010/9/19
A capillary-based pitch-variable array spotter, designed to dispense solutions in nanoliter volumes with high precision and density, was used to immobilize gene probes on a microelectrode array chip....
Determination of Linear Short Chain Aliphatic Aldehyde and Ketone Vapors in Air Using a Polystyrene-coated Quartz Crystal Nanobalance Sensor
Linear Short Chain Aliphatic Aldehyde and Ketone Vapors Polystyrene-coated Quartz Crystal Nanobalance Sensor
2010/9/17
A polystyrene coated quartz crystal nanobalance (QCN) sensor was developed for use in the determination of a number of linear short-chain aliphatic aldehyde and ketone vapors contained in air. The qua...
Development of a ZnO-modified Light-Scattering Sensor for the Detection of Alcohols
a ZnO-modified Light-Scattering Sensor Alcohols
2010/9/20
A light-scattering sensor that incorporated zinc oxide (ZnO) nanoparticles was developed and characterized in this study. Evenly distributed nanostructured ZnO materials were formed on the sensing ele...
High selectivity flow sensor for gallic acid
flow sensor chemiluminescence immobilized reagents gallic acid
2009/10/29
A novel chemiluminescence(eL)sensor for gallic acid combined flow—injection analysis was presented.The analytical reagents involved in the CI reaction,including luminol and ferricyanide,were both immo...
Potentiometric Utility of the New Solid-State Sensor Based on Crowned Ionophore for the Determination of K+
Ion-selective electrodes Solid-state contact PVC-membrane K+ determination
2010/4/16
All solid-state contact poly vinyl chloride (PVC) membrane potassium-selective electrode has been developed. The construction of the ion selective electrode membrane was organized using ionophore 4,4'...
Diphenylthiocarbazone Immobilized on the Triacetyl Cellulose Membrane as an Optical Silver Sensor
Optical sensor Ag+ ions diphenylthiocarbazone
2010/4/16
An optical sensor for the direct measurement of silver was developed. The basic element of this optode is the immobilization of diphenylthiocarbazone on a triacetyl cellulose membrane. This optode has...
N,N`-Bis(1`-hydroxy-2`-acetonaphthone)propylenediamine: Synthesis, Extractive Properties, and Use as an Ionophore in a Cu(II)-Selective Potentiometric Sensor
propylenediamine Synthesis, Extractive Properties Use as an Ionophore Selective Potentiometric Sensor
2010/4/16
The binding ability of N,N'-bis(1'-hydroxy-2'-acetonaphthone)propylenediimine (H2L) towards metal ions was investigated by performing liquid-liquid extraction experiments to extract Cu2+, Ni2+, Co2+, ...
专著信息
书名
Chemiluminescence microfluidic system sensor on a chip for determination of glucose in human serum with immobilized reagents
语种
英文
撰写或编译
作者
Yi Lv,Zhujun Zhang,Funan Chen
第一作者单位
出版社
Talanta 200...